APEXAdvance Plant Excellence

Industries

Three buyers, three reasons to say yes

The same console, read three ways.

Generation company or IPP

One console for a mixed fleet. Solar, battery storage, geothermal, coal, LNG and gas plants.

  • Every plant and technology on one screen
  • Portfolio reports led by recoverable value
  • Availability in GADS / IEEE 762 terms
  • Curtailment revenue journalled for the grid
  • Steam field management for geothermal

Utility or electric cooperative

Know your substations before they fail. Substations, feeders, distribution utilities and electric cooperatives.

  • Transformer and switchgear condition faceplates
  • Thermal alarms on busbars and terminations
  • IEC 60870-5-104 and DNP3 without extra drivers
  • Door access across unmanned substations

Industrial or commercial facility

Protect the electrical room. Factories, economic zones, data centres, hospitals and large buildings.

  • Thermal watch on switchgear and cables, 24/7
  • Modbus and OPC UA to the PLCs you have
  • Guided alarm response for a small team
  • Replay evidence for insurers and auditors

Generation companies and IPPs

One console for a mixed fleet

Solar, battery storage, geothermal, coal, LNG and gas plants on one screen, each with the view its technology needs. The questions a portfolio asks every month are answered on screen, not in a spreadsheet.

  • Losses with an owner and a cost. Theoretical energy decomposed to delivered, soiling and curtailment included, with cleaning ranked by payback.
  • Availability in GADS / IEEE 762 terms. The figure you report is the figure the console shows.
  • Forecast by technology. 24-hour outlook with a confidence band, and a 7-day view for the maintenance window.
  • Geothermal upstream of the turbine. Steam field layout and deliverability, decline projection and the drilling needed to hold output.
Loss analysis: fleet loss waterfall, per-site deficit, cleaning schedule ranked by payback and the curtailment journal
Screens shown use simulated demonstration data.
24-hour fleet output forecast with a confidence band, broken down by technology
Screens shown use simulated demonstration data.
Geothermal generation view: unit-by-unit output, steam, NCG and equipment health for eleven plants
Screens shown use simulated demonstration data.

Utilities and electric cooperatives

Know your substations before they fail

Substations, feeders and unmanned sites on one map, with the condition of the asset rather than a list of raw points. IEC 60870-5-104 and DNP3 are native, so the RTUs you already have are the only hardware you need.

  • Single-line diagrams generated from the device tree. Breakers and transformers show their live state; any element opens its faceplate.
  • Transformer and switchgear faceplates. DGA, tap position, oil and winding temperature; SF₆ density and contact wear; thermal hot spot on terminations.
  • Alarm console with ISA-18.2 shelving. A nuisance alarm leaves every other screen but stays visible here, with its remaining time.
  • Door access in the same console. Lock, relay and door state for every unmanned site, grouped by substation.
Single-line diagram generated from the device tree: grid, revenue meter, transformer, HV main, MV bus and feeders
Screens shown use simulated demonstration data.
Alarm console with priority, acknowledgement and ISA-18.2 shelving
Screens shown use simulated demonstration data.
Door access: eighteen doors across five geothermal sites, grouped by plant, every reading badged as never read
Screens shown use simulated demonstration data.

Industrial and commercial facilities

Protect the electrical room

Factories, economic zones, data centres, hospitals and large buildings run on a few switchboards nobody watches between inspections. APEX watches them 24/7 with radiometric thermal cameras and keeps the evidence.

  • Thermal watch on switchgear, busbars and cable terminations. Alert and alarm setpoints per camera; a horn on every screen until someone acknowledges.
  • Modbus and OPC UA to the PLCs and meters you have. Read-only, with each device’s comms quality on screen.
  • Guided alarm response for a small team. Threshold, likely causes and the checks that can be made from the desk.
  • Replay evidence for insurers and auditors. Event clips with the thermal values at the playhead, from a 3-second data track recorded alongside the video.
Camera wall: radiometric thermal and HD visual streams from one dual PTZ camera, with an 8 by 6 section grid
Screens shown use simulated demonstration data.
Thermal history and analytics: temperature against irradiance with alert and alarm bands, and APEX insights with evidence and confidence
Screens shown use simulated demonstration data.
Event replay with thermal values at the playhead and the section maxima for that moment
Screens shown use simulated demonstration data.

Built for Philippine operations

The grid, the market and the reporting you already answer to

NGCP grids

Plants grouped by the Luzon, Visayas and Mindanao grids on the fleet map and the grid mesh, with frequency against nominal on the Remote Control Center wall.

WESM dispatch

Dispatch compliance per unit on the Remote Control Center, and every grid instruction journalled with its window, the energy held back and its value.

GADS availability

Availability and forced-outage figures in GADS / IEEE 762 terms, on screen and in the portfolio report, so the number you publish is the number the console shows.

How APEX compares

Against the tools a power or electrical operation typically runs today

CapabilityTraditional SCADA / HMIOEM equipment portalThermography softwareAPEX
Multi-protocol data hubPer-driver licencesOwn equipment only—5 protocols in, OPC UA out
Generation and substations, one viewUsually one siteOne vendor’s fleet—Solar, BESS, geothermal, coal, LNG, substations
Electrical asset conditionRaw pointsOwn units only—Transformer, switchgear, feeder faceplates
Radiometric thermal monitoring——Stand-alone, no plant dataBuilt in, alarms into the console
Synced thermal + visual recording——Snapshots24/7, one clock, data track
Losses and curtailment with a cost—Partial, no cost—Cause, owner, cost, payback
Automated executive reportsAdd-on moduleBasic exportPer-image reportPDF / Excel with GADS indexes
Forecast and explainable analytics—Vendor black box—Method shown on the AI/ML page
Alarm analytics and guided responseAlarm list onlyAlarm list only—Journal, shelving, causes, manuals
Provenance badges on every value———Measured / modelled / simulated

Columns describe typical products in each class, not any one vendor.

See APEX run on a simulated fleet, then scope your plants

Showcase mode walks the important functions in about four minutes. After that we list your SCADA points, protocols and camera positions.